EasyPACK-I 67-130 kW Scroll

Special Energy Saving Solutions for Commercial Buildings and Residences
With inverter compressor
Sensitive and efficient power modulation
Integrated master/slave device control
Plug & Play Unit with heat recovery

Eurovent Certified High Performance
High Energy Efficiency & Comfort in All Seasons
Wide and Smart Options
Increased outdoor operating limits

 



STRUCTURAL FEATURES


Compressor: Heremetic scroll type compressor with inverter, thermal protection and sump heater (1+i).
scroll kompresör.
• Continuous capacity update at partial loads.
Evaporator: Closed cell, stainless steel plates with polyurethane foam insulation and water flow differential pressure switch.
Condenser: Developed with copper pipes and aluminium finned batery or microchannels accordind to models and dimensions.
Fan: External rotor axial fan equipped with internal thermal protector and protection grids.
Control: Microprocessor control with Adaptive Function Plus.
Structure: Galvanized and powder polyester paint coated structure.

STANDARD FEATURES


•Circuit breaker switches for fan and compressor.
•High and low pressure indicator.
•Master / slave control of up to parallel connected 4 units.
•Clock board

VERSIONS


• TCAITY: High efficiency version, cooling only (T).
• TCAIQY: Super silent version, cooling only (Q).
• THAITY: Heat pump unit.
• THAIQY: Super silent version, heat pump unit.

 


FACTORY FITTED ACCESSORIES


• Single or double pump. 1 master and 1 spare aplication in double pump options.Standard/high pressure versions of pumps are optional.
• TANK AND PUMP UNIT: Expansion tank, manual air discharge valve, with safety valve and water side pressure indicator 230-440 depending on model storage tank up to liter. Low and high pressure versions of the pumps are available.
• Variable Primary Flow (VPF) control.
• Desuperheater.
• 100% heat regain option.
• Condensation control with EC motor fans. (standard for 270-2100 models).
• Condensation control with high pressure fans (T version).
• Power factor correction capacitor (Cosφ > 0,94).
• Forced limit of power consumption.
• Forced noise limit.
• Soft starter.
• Compressor noise insulator.
• Noise insulation.
• Cooling circuit suction and discharge valves.
• Refrigerant leak detector.
• Refrigerant circuit high and low pressure indicators.
• Double safety valves.
• Metal filters or battery protection grids.
• Epoxy coated micro-channel condenser.
• Copper / copper or copper / aluminum pre-painted aluminum batteries.
• Minimum / maximum power supply control.
• Digital input for double set point.
• Setpoint shift (4-20 mA analog signal).
• Evaporator heater, electrical panel, storage tank for frost protection, electric pumps and heat exchangers for heat regain, if available.
• Interfaces for serial communication with other devices.
• Rubber vibrators.


Last Update 25.01.2021 20:20:24