STRUCTURAL FEATURES
• Compressor: Hermetic, scroll type compressor, thermal protection and oil sump heater are added.
• 2, 3 or 4 capacity stages with high efficiency at partial loads.
• Water Side Heat Exchangers: Closed cell, completed with stainless steel plates with polyurethane foam insulation and water flow differential pressure switch.
• Air Side Heat Exchangers: Finned coils or microchannels developed with copper pipes and aluminum fins according to models and dimensions.
• Fan: İç External rotor electric axial fans equipped with internal thermal protection and protection grilles.
• Control: Microprocessor control with Adaptive Function Plus.
• Structure: Galvanized and powder polyester paint coated steel structure.
STANDARD FEATURES
•Compressor and fan thermal overload switches.
•High / low pressure indicator for the refrigerant circuit.
•Electronic expansion valve.
•Clock board showing date / time.
VERSIONS
B - Standard version ( TCAEBY)
S - Quiet version with soundproof compressor compartment, low speed fans and large condenser section (TCAESY-THAEST)
FACTORY FITTED ACCESSORIES
• Shell and Tube evaporatOr.
• Single or double electric pump with automatic pump that can be used in standby mode. Standard / high pressure versions of the pumps are optional.
• Structural storage tank of 300-700 liters (depending on model) and single or double pump TANK & PUMP, with expansion tank, air discharge valves, safety valve and water side pressure indicator attached.
• Variable flow pump management.
• Super steam cooler.
• 100% heat regain.
• Electronic expansion valve.
• -10 ° C condensation control.
• -15 ° C condensation control with EC motor fans (standard in Q version).
• Condensation with overpressure fans.
• Power factor correction capacitors (Cosf> 0.91).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameters measuring device.
• Optimised energy efficiency.
• Soft starter.
• Noiseproof compressor box.
• Compressor sound blankets.
• Refrigerant leak detector.
• High/low pressure indicators for each refrigerant circuit.
• Metal filters or coil guard grids.
• Copper / copper or copper / pre-painted aluminum coils.
• Digital input for double set point.
• Setpoint shift (4-20 mA analog signal).
• Evaporative antifreeze resistor, buffer tank, pumps and heat exchangers for heat regain, if applicable.
• Buffer tank integrative heaters.
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Anti-vibration props.